DMS 903

Back

Fully automatic 6-axis goniometer for large-format displays

csm_DMS903_Goniometer_Display_683x626px_retu_1f503d09ec
Description
Applications
Technical data
Video
Description
Applications
Technical data
Video
Maximum automation for quality control and lab

The DMS 903 is ideal for the photometric and colorimetric analysis of large-format displays. The measuring system is based on a 6-axis goniometer for determining the viewing angle-dependent properties of large displays.

 

It is used in quality control, as well as in research and development and permits the analysis of samples up to a diagonal of 1800 mm (approx. 72”) and a measurement surface diagonal of 1270 mm (approx. 50”).

 

Product details:

 

  • Characterization of emissive, transmissive, reflective and transflective displays
  • 6 motorized axes for viewing angle scan and surface scanning of samples, without rotation of the sample during measurement
  • Optional array spectrometer for precise radiometric and photometric measurements
  • Analysis of all photometric and colorimetric properties as a function of viewing angle, electrical control, time and temperature (optionally with temperature control chamber)
  • Optional specular illumination for evaluation of the reflectance characteristics (e.g. BRDF) and diffuse light source with adjustable diameter (1° to 15°) for the simulation of ambient lighting conditions
  • Motorized microscope aperture and integral alignment camera
  • Extensive accessories for testing in varying lighting conditions and temperatures

 

DMS accessories

 

  • Combined light meters: microscope, photometer, spectrometer
  • Temperature control chamber
  • Light sources and illumination units
  • Unit for sample control

 

DMS software

 

  • Software packages DMSControl (controller) and ViPer (preparation and evaluation of readings)
Examples of applications
DMS 903 – Technical data
Parameter Properties of DMS 903

θ inclination angle

0° bis 80°

Φ rotation angle

0° bis 360 °

Reflective illumination angle

0° bis 70°

Min. step θ / Φ / Refl. illumination

0,01°

X/Y transition

X: ±300 mm; Y: ±225 mm

Z transition

280 mm

Min. step X/Y/Z

0,01 mm

Sphere of confusion (all axis)

300 µm

Max. diagonal

1800 mm / 72“

Max. diagonal for motorized x-y scanning

1270 mm / 50“

Max. thickness

280 mm

The detailed measurement conditions under which the specified values have been determined can be looked up in the data sheets and brochures or requested from Instrument Systems.
 
Video
Find Us on WeChat
QRcode