Based on a fully motorized 6-axis goniometer, the DMS 803 is used for convenient determination of the luminance, contrast and color properties of small to medium-sized displays at different viewing angles with variable electrical control.
Its scope of use embraces multiple applications in research & development and quality control. A wide range of lighting accessories and temperature control chambers make the DMS 803 particularly suitable for the characterization of displays for mobile applications (smartphone, tablet PC).
Product details:
- Characterization of emissive, transmissive, reflective and transflective displays
- Fully motorized 6-axis positioner with electrical control, photometer or spectroradiometer, lighting, PC and software
- Surface scan: max. 100 x 100 mm for analyzing the homogeneity of luminance, contrast and color over the surface
- Optional temperature control chamber
- Analysis of all photometric and colorimetric properties as a function of viewing angle, electrical control, temperature and time
- Extensive range of accessories for testing under varying lighting conditions and temperatures
DMS accessories
- Combined light meters: microscope, photometer, spectrometer
- Temperature control chamber
- Light sources and illumination units
- Unit for sample control
- Scan surface extension
DMS software
- Software packages DMSControl (controller) and ViPer (preparation and evaluation of readings)
Illumination devices for our DMS measuring systems
DHS – Diffusing hemisphere for the measurement of contrast in reflective mode of operation
SDR – Integrating Sphere for measurement of spectral reflection and display performance under ambient illumination
VADIS – Diffuse light source for measurement of surface scattering and display performance under ambient illumination
PID – Parallel illumination device for measurement of BRDF (Bidirective Reflectance Distribution Function)
PLS – Point light source for measurement of e.g. BRDF, specular reflectance
Parameter | Properties of DMS 803 |
θ inclination angle |
0° bis 90° |
Φ rotation angle |
0° bis 360 ° |
Reflective illumination angle |
0° bis 90° |
Min. step θ / Φ / Refl. Illumination |
0,01° |
X/Y transition |
±50 mm |
Z transition |
250 mm |
Min. step X/Y/Z |
0,01 mm |
Sphere of confusion (all axis) |
100 µm |
Max. diagonal |
600 mm / 23“ |
Max. diagonal for motorized x-y scanning |
459 mm / 18“ |
Max. thickness |
250 mm |